I’ve started a series of video about battery testing on my YouTube channel, you can watch first video here.
On this page, I’ll keep a summary table about capacities of different batteries on different currents, and also here you can download raw .csv voltage-time data, if you’re interested.
In table you can find battery name, capacity that it gave at specified current, capacity that it gave after about 12h rest (second discharge is performed at 0.1A in all cases) to estimate how much capacity remains after first discharge, and efficiency, which I calculated as (capacity at first discharge)/(capacity at first discharge + capacity at second 0.1A discharge).
CSV files with raw voltage-current graphs can be found below the table.
Name | Current | Capacity | Capacity after 12h | Efficency |
Auchan white | 0.1A | 2001 | n/a | 1 |
Auchan white | 0.2A | 1576 | 440 | 0,781 |
Auchan white | 0.5A | 432 | 1434 | 0,231 |
Auchan alkaline | 0.1A | 2237 | n/a | 1 |
Auchan alkaline | 0.2A | 1792 | 463 | 0,794 |
Auchan alkaline | 0.5A | 509 | ||
Auchan Hi-perf | 0.1A | 2225 | n/a | 1 |
Auchan Hi-perf | 0.2A | 1788 | 442 | 0,801 |
Auchan Hi-perf | 0.5A | 446 | ||
Carrefour i-Tech | 0.1A | 2414 | n/a | 1 |
Carrefour i-Tech | 0.2A | 2045 | 382 | 0,843 |
Carrefour i-Tech | 0.5A | 1120 | 1235 | 0,476 |
Carrefour alkaline | 0.1A | 2280 | n/a | 1 |
Carrefour alkaline | 0.2A | 1888 | 411 | 0,821 |
Carrefour alkaline | 0.5A | 977 | 1200 | 0,449 |
Lexman standard | 0.1A | 2199 | n/a | 1 |
Lexman standard | 0.2A | 1822 | 112 | 0,942 |
Lexman standard | 0.5A | 1045 | 865 | 0,547 |
Lexman Intensive | 0.1A | 2167 | n/a | |
Lexman Intensive | 0.2A | 1814 | 213 | 0,895 |
Lexman Intensive | 0.5A | 742 | 1164 | 0,39 |